SUN2000-150k-MG0

  SMART PV CONTROLLER

  SOLID POWER OUTPUT, PROVEN SAFETY MAX EFFICIENCY 98.4%
GET QUOTE

SUN2000-150K-MG0 Smart PV Controller

Technical Specification SUN2000-150K-MG0
  Efficiency
Max. efficiency European efficiency
European efficiency 98.4%
Input
Max. Input Voltage 1 1,100 V
Max. Current per MPPT 48A
Max. Current per Input 23A
Max. Short Circuit Current per MPPT 66A
Start Voltage 200 V
MPPT Operating Voltage Range 2 200 V ~ 1,000 V
Number of MPP trackers 7
Max. input number per MPP tracker 3
Output
Nominal AC Active Power 150,000 W
Max. AC Apparent Power 165,000 VA
Max. AC Active Power (cosφ=1) 165,000 W
Nominal Output Voltage 380 V/400 V/480Vac
Rated AC Grid Frequency 50 Hz / 60 Hz
Nominal Output Current 227.9 A @380 V, 216.5 A @400 V, 180.4A @480Vac
Max. Output Current 253.2 A @380 V, 240.5 A @400 V, 200.5A @480Vac
Adjustable Power Factor Range 0.8 leading… 0.8 lagging
alternating current THDi <1%
Protection
Anti-islanding Protection Yes
AC Overcurrent Protection Yes
DC Reverse-polarity Protection Yes
PV-array String Fault Monitoring Yes
DC Surge Arrester Type II
AC Surge Arrester Type II
DC Insulation Resistance Detection Yes
Residual Current Monitoring Unit Yes
Smart String Level Disconnector Yes
Arc Fault Protection Yes
Terminal Temperature Detection Yes
PID Recovery Yes
PV Ground-Fault Protection Yes
Communication
Display LED indicators; WLAN adaptor + FusionSolar APP
RS485 Yes

 

USB Yes
Smart Dongle-4G Smart Dongle – 4G / WLAN (Optional)
Monitoring BUS (MBUS) Yes (isolation transformer required)
General Data
Dimensions (W x H x D) 1,000 x 710 x 395 mm
Weight (with mounting plate) 102 kg
Operating Temperature Range -25°C ~ 60°C
Cooling Method Smart Air Cooling
Max. Operating Altitude 4,000 m (13,123 ft.)
Relative Humidity 0 ~ 100%
DC Connector Amphenol HH4
AC Connector Waterproof Connector + OT/DT Terminal
Protection Degree IP66
Topology Transformerless
Standard Compliance (more available upon request)
Certificate EN 62109-1/-2, IEC 62109-1/-2, IEC 62116, IEC 61727, IEC 60068, IEC 61683
Grid Connection Standards VDE-AR-N4105, EN 50549-1, EN 50549-2, RD 661, RD 1699, C10/11

 

  • This datasheet only shows Preliminary Version, the information may change. Please contact with HW local supplier for the latest version.

* 1 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.

* 2 Any DC input voltage beyond the operating voltage range may result in inverter improper operating.

Click the button below to Download the Technical Specification Document

Download